Temperature control for over-heating protection
InMotion, Gotway, and KingSong electric unicycles are equipped with built-in protection to warn you when your device is overheating. Overheating can occur in stressful situations such as aggressive acceleration, hill climbing, or fast speeds.
On KingSong EUCs, Pedal tilt-back will engage when the control board temperature reaches 80℃, or when the motor temperature reaches 120℃. The internal fan will be activated when the control board temperature exceeds 50℃ and will automatically deactivate when the temperature falls below 40℃