King Song Error Codes

KingSong EUCs Error Code
Error Code Description
*Note KS-S22 displays only last 2 digits of error code
2235 Sensor data is reversed, or line fault, this sensor has now been turned off.
2236 Sensor B is not connected or the sensor is damaged, the sensor has been closed for use.
2237 Sensor data A is reversed, this sensor is closed.
2238 Sensor A is not connected or the sensor is damaged, the sensor has been closed for use.
2239 The voltage is too high, please do not ride downhill for an extended time.
2240 The voltage is too high, please remove the charger.
2241 Low battery, please charge.
2242 Gyroscope error, please contact your seller and replacement motherboard.
2243 The output current of the main board has exceeded. Please check if the motor is damaged or if the phase line is shorted.
2244 Please check if the motor hall line connection and is functioning normally.
2245 No serial number or serial number error
2246 The motor temperature is too high, please stop and ride after the it has cooled down.
2247 The motherboard temperature is too high, please stop and ride after the it has cooled down.
2248 The output current is at max, please ride with caution.
202 Over Current or locked rotor.
203 The motor is blocked, please check whether the motor is rotating smoothly or remove obstacles before riding.
205 Drive Cruit is not functioning correctly, please restart or replace drive circuit.
206 The motherboard output wire has short circuited, please check whether the battery output wire has short circuited or whether the motherboard MOS is damaged.
207 Gyroscope failure, please replace motherboard.
217 Motor Hall sensor error, please check the hall ensor and repair accordingly.
221 Motor is experiencing high temperature, please allow Motor to cool down before riding again.
222 MOS is experiencing high temperature, please allow MOS to cool down before riding again.
228 Serial Number Error.
218 Overpower, please avoid over-accelerating or climbing steep hills.
219 Device is outputting at max.
220 Motherboard output over votlage, or motor is blocked. Please ride with caution.
223 Charging is over voltage or over current.
229 Low voltage, please charge your device!
231 Overvoltage, please beware of your safety and avoid riding downhill.
232 Lift switch is out of order, please release the handlebar or check whether the lift switch sensor has experienced a short circuit.
230 Reserve power is missing, please replace motherboard.
1208 mttool,vol err
1209 mttool,over time
1210 mttool,block err
1211 mttool,speed err
208 the coef of batvol have no just
227 BMS get no data
226 BMS Warnning
105 be voltage detect need calibration
224 The battery reaches the preset charging value

BMS Error Code
Error Code Description
5001 Hardware short-circuit and software short-circuit
protection instructions and solutions: battery protection circuit short-circuit protection, please stop using the machine immediately, check where there is a short-circuit problem, unplug the charger, stop riding, stand or turn off for 1 minute, etc. After checking, if it can't Back to normal, need to be repaired.
5002 Over-charging protection
instructions and solutions: If the charging current of the battery exceeds (reference value: 7A), please stop charging immediately, unplug the charger, wait for about 1 minute, and the machine will automatically release the protection.
5003 Over-discharge protection
instructions and solutions: If the battery discharge current exceeds (reference value: 40A), please stop the machine immediately, or you can also plug in the charger to charge, wait for about 10S, and the machine will automatically release the protection.
5004 Single-cell overvoltage protection
description and treatment plan: If the voltage of the single-cell battery exceeds (reference value: 4.25V), please stop charging immediately, remove the charger for 10S, or run the machine, and wait for the voltage to drop below (4.15V), then The machine will automatically release the protection.
5005 Total voltage over-discharge protection
description and treatment plan: If the total battery voltage is lower than (reference value: 72.0V), please stop using the machine immediately, and charge the machine in time. When the total voltage is higher than the recovery voltage (90V), the machine will automatically release Protect.
5006 Ambient low temperature, high ambient temperature
Protection instructions and treatment plan: battery temperature The ambient temperature (reference value: -30℃~70℃) has seriously exceeded the battery protection limit. Please immediately improve the ambient temperature where the battery is located.
5007 High temperature discharge protection
instructions and treatment plan: When the battery temperature is higher than (reference value: 60°C) during discharge, please stop using the machine immediately. When the temperature is lower than 50°C, the machine will automatically release the protection.
5008 High temperature charging protection
instructions and solutions: If the charging temperature of the battery exceeds (reference value: 45°C), please stop charging immediately. When the temperature is lower than 40°C, the machine will automatically release the protection.
5009 MOSFET high temperature
Protection instructions and treatment plan: The charging or discharging circuit temperature (reference value: 95℃) is seriously higher than the battery protection limit, please stop charging or stop using the machine immediately and wait for recovery.
5024 Total voltage and overvoltage protection
instructions and solutions: when charging, the total voltage is higher than (reference value: 126.5V), please stop charging immediately, remove the charger for 10S, or run the machine, wait for the voltage to drop below (124.5V) , the machine will automatically release the protection.
5025 Single-cell over-discharge protection
instructions and solutions: If the voltage of the single-cell battery is lower than (reference value: 2.50V), charge the machine in time. When the minimum single-cell voltage is higher than the recovery voltage (3V), the machine will automatically release the protection.
5027 Discharge low temperature protection
instructions and treatment plan: When the battery temperature is lower than (reference value: -20℃) during discharge, please stop using the machine immediately and improve the ambient temperature where the battery is located. When the temperature is higher than -10℃, the machine will automatically release the protection .
5028 Low charging temperature Protection
instructions and treatment plan: If the charging temperature of the battery is lower than (reference value: -5℃), please stop charging and improve the ambient temperature where the battery is located. When the temperature is higher than 0℃, the machine will automatically release the protection.
5010 Sampling failure, cell failure
Fault description and solution: There is a failure in the protection board circuit, please stop using the machine immediately, check and repair it.
5011 NTC fault
Fault description and solution: The temperature sensor is faulty. If it cannot be recovered, it needs to be repaired.
5012 Charging MOS fault
Fault description and solution: If the charging circuit of the protection board is faulty, please stop using the machine and check and repair. The method of automatic recovery of charging MOS fault: plug in the charger, after 2~5 seconds, under normal circumstances, the fault will be automatically eliminated.
5033 Working power failure
Fault description and solution: If the working power supply of the protection board is faulty, please stop using the machine immediately and check and repair it.
5013 Total voltage and low voltage alarm
description and processing plan: the total voltage (reference value: 90.0V~126.2V) is low (less than 90V), please charge it in time, and when the single voltage is higher than 3V and the total voltage is higher than 90V, the alarm will be displayed. automatically eliminated.
5014 Total voltage and overvoltage alarm
description and solution: the total voltage (reference value: 90.0V~126.2V) is too high (greater than 126.2V), please stop charging in time, and use it normally. After the total voltage is lower than 126.2V, the alarm will be issued will be automatically removed.
5034 MOS high temperature Alarm
description and solution: Please confirm whether the MOS temperature is higher than (reference value: 90°C) in time. First, stop the machine from working, stop charging, and wait for a period of time. When the MOS temperature is lower than 90°C, the alarm will be automatically cleared.
5035 Ambient low temperature and high ambient temperature
Alarm description and solution: The ambient temperature of the battery (reference value: -20°C~65°C) exceeds the limit, please confirm the ambient temperature of the machine in time, and select the charging at the appropriate temperature or riding environment.
5036 Discharge low temperature, discharge high temperature
Alarm description and solution: The battery temperature (reference value: -10℃~57℃) exceeds the limit, please stop using the machine in time, or reduce the power consumption of the machine.
5037 Charging low temperature, charging high temperature
Alarm description and solution: The battery temperature (reference value: 3℃~45℃) exceeds the limit, please stop charging in time, or check whether the charging current (reference value: 8A) is too large.
5038 Discharge overcurrent Alarm
description and solution: Please confirm in time that the discharge current of the left and right batteries exceeds -35A (the negative sign indicates discharge). As long as the current is less than 35A, the alarm can be automatically eliminated.
5039 Charging overcurrent alarm
description and solution: Please confirm whether the charging current (reference value: 6A) is too large (greater than 6A) in time, as long as the charging current is less than 6A, or stop charging, the alarm can be automatically eliminated.
5015 Cell low voltage Alarm
description and solution: The single battery voltage (reference value: 3.000V~4.22V) is low (less than 3V), please charge it in time, wait until the single cell voltage is higher than 3V and the total voltage is higher than 90V , the alarm will be automatically cleared.
5016 Low battery alarm Alarm
description and solution: The battery is low (reference value: 10%), please charge it in time, and the alarm will be automatically cleared when the battery power is higher than 10%.
5017 Cell high voltage Alarm
description and solution: The single battery voltage (reference value: 3.000V~4.22V) is too high (greater than 4.22V), please stop charging in time, and use it normally, and wait until the single battery voltage is lower than 4.22V , the alarm will be automatically cleared.
5018 Discharge high temperature Alarm
description and solution: When the battery temperature exceeds 90°C when riding or the motor is running, please stop riding or stop using the machine in time. When the temperature is lower than 90°C, the alarm will be automatically cleared.
5019 Charging high temperature Alarm
description and solution: When the battery temperature exceeds 40℃ during charging, please stop charging in time, or strengthen the heat dissipation of the machine. When the temperature is lower than 40℃, the alarm will be automatically cleared.